Brusa Charger Programming and Monitoring 11/6/2022 Serial Port Setup Plug in Keyspan USB to serial adapter Go to Device Manager, COM and LPT ports, Keyspan USB to serial adapter Properties Baud Rate 19200 Data 8 bit Parity none Stop 1 bit Flow Control Xon/Xoff Advanced Port number COM1 Charger Programming Install Brusa Charge Star, chst304e.exe Launch Charge Star Connect to charger Read profile from charger Set stage 1: battery capacity filling Nominal pack voltage 153.6 >> 140.8 with 11 modules Max mains 25A NLG operating mode Auto Shut off immediately if Voltage >185V -- 175V caused errors, maybe it could be lower than 185V? Ah > 120 Charge time >22h I phase 25 amps (constant current) U phase 175V (constant voltage) >> 170V now that cells aren't as balanced; 175V turns red on 120V due to unbalanced cells >> 155V now that module 12 is dead and removed Switch to Stage 2 when below 2 amps Set stage 2: cell balancing I phase 1 amp (constant current) U phase 175V (constant voltage) >> 170V now that cells aren't as balanced; 175V turns red on 120V due to unbalanced cells >> 155V now that module 12 is dead and removed Switch to Stage 3 when greater than 720 minutes (12 hours) Set stage 2 to 0 amps, 0 V Write profile to charger Disconnect from charger Charger Monitoring Install TeraTerm Launch TeraTerm New Connection: Serial COM1 Setup, Serial Port; same parameters as in serial port setup above Control, Reset Terminal Enter; "Login:" prompt comes up Type "monitor" and press enter Voltages, currents and temperatures show and get updated every few seconds